SERVICE DATA AND SPECIFICATIONS (S.D.S.) - Inspection and Adjustment
EF & EC-725spec tableIdle compensator specs differ for GA16DS 4WD / B13 GA16DS for Europe and Gulf standard vs other models.
SERVICE DATA AND SPECIFICATIONS (S.D.S.) — GA13DS, GA14DS & GA16DS
Inspection and Adjustment
A.T.C. AIR CLEANER
A.T.C. air cleaner - Intake manifold vacuum -kPa (-mbar, -mmHg, -inHg)
Below 4.7 (47, 35, 1.38)
Atmospheric temperature °C (°F) - Below 38 (100)Cold air
Atmospheric temperature °C (°F) - Above 48 (118)Cold air
Above 16.7 (167, 125, 4.92)
Atmospheric temperature °C (°F) - Below 38 (100)Hot air
Atmospheric temperature °C (°F) - Above 48 (118)Cold air
A.T.C. air cleaner - Vacuum motor -kPa (-mbar, -mmHg, -inHg)
Opening starts
Value6.7 ± 2.0 (67 ± 20, 50 ± 15, 1.97 ± 0.59)
Fully open
ValueOver 13.3 ± 3.3 (133 ± 33, 100 ± 25, 3.94 ± 0.98)
IDLE COMPENSATOR
Idle compensator - Unit: °C (°F)
Idle compensator partially opens (No. 1)
GA16DS 4WD, B13 GA16DS for Europe, and Gulf standard55 - 65 (131 - 149)
Others55 - 65 (131 - 149)
Idle compensator partially opens (No. 2)
GA16DS 4WD, B13 GA16DS for Europe, and Gulf standard65 - 75 (149 - 167)
Others—
Idle compensator fully opens
GA16DS 4WD, B13 GA16DS for Europe, and Gulf standardAbove 65 (149) (No. 1) / Above 75 (167) (No. 2)
Others65 (149)
IGNITION COIL
| Specification | Value |
|---|---|
| Primary voltage | 12V |
| Primary resistance [at 20°C (68°F)]at 20°C (68°F) | Approximately 1Ω |
| Secondary resistance [at 20°C (68°F)]at 20°C (68°F) | Approximately 10kΩ |
Primary voltage
12V
Primary resistance [at 20°C (68°F)]at 20°C (68°F)
Approximately 1Ω
Secondary resistance [at 20°C (68°F)]at 20°C (68°F)
Approximately 10kΩ
MECHANICAL FUEL PUMP
| Specification | Value |
|---|---|
| Fuel pressure | 20.6 - 34.3 (0.206 - 0.343, 0.21 - 0.35, 3.0 - 5.0)kPa (bar, kg/cm², psi) |
Fuel pressure
20.6 - 34.3 (0.206 - 0.343, 0.21 - 0.35, 3.0 - 5.0)kPa (bar, kg/cm², psi)
DISTRIBUTOR AND CRANK ANGLE SENSOR
| Specification | Value |
|---|---|
| Firing order | 1-3-4-2 |
| Rotating direction | Counterclockwise |
| Air gap*Only for distributor | 0.3 - 0.5 (0.012 - 0.020)mm (in) |
| Cap insulation resistance | More than 50MΩ |
| Rotor head insulation resistance | More than 50MΩ |
| Cap carbon point length | 10 (0.39)mm (in) |
Firing order
1-3-4-2
Rotating direction
Counterclockwise
Air gap*Only for distributor
0.3 - 0.5 (0.012 - 0.020)mm (in)
Cap insulation resistance
More than 50MΩ
Rotor head insulation resistance
More than 50MΩ
Cap carbon point length
10 (0.39)mm (in)
NOTE