Diagnostic Procedure 37 (Cont'd) - Inhibitor switch
EF & EC-342flowchartInput signal circuit check lists L.H.D. harness connectors F33/M37, M11/E104, E5/E224 and R.H.D. harness connectors F6/E15, E54/E202.
Diagnostic Procedure 37 (Cont'd) - Inhibitor switch (continued from F)
1
A (continued from previous page)
2
F: CHECK INPUT SIGNAL CIRCUIT. 1) Check harness continuity between E.C.U. terminal 35 and terminal b. Continuity should exist.
N.G.
Check the following. - Harness connectors F33, M37 (L.H.D. models) - Harness connectors M11, E104 (L.H.D. models) - Harness connectors E5, E224 (L.H.D. models) - Harness connectors F6, E15 (R.H.D. models) - Harness connectors E54, E202 (R.H.D. models) - Harness continuity between E.C.U. and inhibitor switch. If N.G., repair harness or connectors.
Check the following. - Harness connectors F33, M37 (L.H.D. models) - Harness connectors M11, E104 (L.H.D. models) - Harness connectors E5, E224 (L.H.D. models) - Harness connectors F6, E15 (R.H.D. models) - Harness connectors E54, E202 (R.H.D. models) - Harness continuity between E.C.U. and inhibitor switch. If N.G., repair harness or connectors.
O.K.
3
CHECK COMPONENT (Inhibitor switch). Refer to "Electrical Components Inspection". (See page EF & EC-352.)
N.G.
Replace inhibitor relay.
O.K.
4
Check E.C.U. pin terminals for damage or the connection of E.C.U. harness connector.