Nissan 100NX N14 silhouetteN14

Diagnostic Procedure 37 (Cont'd) - Inhibitor switch

EF & EC-341flowchart

Inhibitor switch is for A/T models. Ground circuit check lists L.H.D. harness connectors E5, E224 and R.H.D. harness connectors E54, E202.

Inhibitor switch

Diagnostic Procedure 37 (Cont'd) - Inhibitor switch

1
INSPECTION START
2
D: CHECK OVERALL FUNCTION. 1) Turn ignition switch "ON". 2) Check neutral switch signal in "DATA MONITOR" mode with CONSULT. "N" or "P": ON Except above: OFF -- OR -- 1) Shift selector lever to "P" range. 2) Disconnect E.C.U. harness connector. 3) Turn ignition switch "ON". 4) Check harness continuity between E.C.U. terminal 35 and body ground. Continuity should exist. 5) Shift selector lever to "N" range. 6) Check harness continuity between E.C.U. terminal 35 and body ground. Continuity should exist.
O.K.
INSPECTION END
N.G.
3
E: CHECK GROUND CIRCUIT. 1) Turn ignition switch "OFF". 2) Disconnect inhibitor switch harness connector. 3) Check harness continuity between terminal a and body ground. Continuity should exist.
N.G.
Check the following. - Harness connectors E5, E224 (L.H.D. models) - Harness connectors E54, E202 (R.H.D. models) - Harness continuity between inhibitor switch and body ground. If N.G., repair harness or connectors.
Check the following. - Harness connectors E5, E224 (L.H.D. models) - Harness connectors E54, E202 (R.H.D. models) - Harness continuity between inhibitor switch and body ground. If N.G., repair harness or connectors.
O.K.
4
Disconnect E.C.U. harness connector.
5
A (continues on next page)