Carburetor - Vacuum Break (Cont'd)
EF & EC-168spec tableTemperature thresholds and clearance "R" specs differ by catalyzer and E.G.R. fitment.
Vacuum Break (Cont'd)
Vacuum break temperatures - T °C (°F)
T1
Models with catalyzer and E.G.R.0 ± 4 (32 ± 7.2)
Models without catalyzer, Models with catalyzer without E.G.R.14 ± 4 (57 ± 7.2)
T2
Models with catalyzer and E.G.R.20 ± 4 (68 ± 7.2)
Models without catalyzer, Models with catalyzer without E.G.R.31 ± 4 (88 ± 7.2)
Clearance R - mm (in)
Below T1
Models with catalyzer1.44 ± 0.13 (0.0567 ± 0.0051)
Models without catalyzer1.22 ± 0.14 (0.0480 ± 0.0055)
Above T2
Models with catalyzer2.42 ± 0.32 (0.0953 ± 0.0126)
Models without catalyzer2.15 ± 0.32 (0.0846 ± 0.0126)
Vacuum Break (Cont'd)
- 3In this condition, check clearance "R" between choke valve and carburetor body.
- 4If out of specification, adjust "R" by bending tongue.