Diagnostic Procedure 37 (Cont'd) - Neutral switch
EF & EC-339flowchartGround circuit check lists L.H.D. harness connectors F7, E224 and R.H.D. harness connectors E54, E202.
Neutral switch
Diagnostic Procedure 37 (Cont'd) - Neutral switch
1
INSPECTION START
2
A: CHECK OVERALL FUNCTION. 1) Turn ignition switch "ON". 2) Check neutral switch signal in "DATA MONITOR" mode with CONSULT. Neutral position: ON Except above: OFF -- OR -- 1) Set shift lever to the neutral position. 2) Disconnect E.C.U. harness connector. 3) Check harness continuity between E.C.U. terminal 35 and body ground. Continuity should exist.
O.K.
INSPECTION END
N.G.
3
A: Turn ignition switch "OFF".
4
B: CHECK GROUND CIRCUIT. 1) Disconnect neutral switch harness connector. 2) Check harness continuity between terminal b and body ground. Continuity should exist.
N.G.
Check the following. - Harness connectors F7, E224 (L.H.D. models) - Harness connectors E54, E202 (R.H.D. models) - Harness continuity between neutral switch and body ground. If N.G., repair harness or connectors.
Check the following. - Harness connectors F7, E224 (L.H.D. models) - Harness connectors E54, E202 (R.H.D. models) - Harness continuity between neutral switch and body ground. If N.G., repair harness or connectors.
O.K.
5
Disconnect E.C.U. harness connector.
6
A (continues on next page)