Nissan 100NX N14 silhouetteN14

E.G.R. SYSTEM

EF & EC-719prose procedure

Operation tables differ between CD17 and CD20 engines.

Schematic

Refer to QUICK-GLOW SYSTEM.

Wiring Diagram

Refer to QUICK-GLOW SYSTEM.

Description

The E.G.R. system is designed to control the formation of NOx emission by recirculating the exhaust gas into the intake manifold passage through the E.G.R. control valve.

Operation

CD17

CD17 E.G.R. operation

Below 70 (158)
LoadAll
E.G.R. control solenoid valveOFF (Closed)
E.G.R. control valveClosed
Above 70 (158)
LoadLight load
E.G.R. control solenoid valveON (Open)
E.G.R. control valveOpen
Above 70 (158)
LoadMiddle load
E.G.R. control solenoid valveON (Open)
E.G.R. control valveOpen
Above 70 (158)
LoadHeavy load
E.G.R. control solenoid valveOFF (Closed)
E.G.R. control valveClosed

CD20

CD20 E.G.R. operation

Below 60 (140)
LoadAll
Control solenoid valve - E.G.R. valveOFF (Closed)
Control solenoid valve - Throttle valveOFF (Closed)
E.G.R. control valveClosed
Throttle chamber control valveOpen
Amount of E.G.R. gas
Above 60 (140)
LoadLow load
Control solenoid valve - E.G.R. valveON (Open)
Control solenoid valve - Throttle valveON (Open)
E.G.R. control valveOpen
Throttle chamber control valveClosed
Amount of E.G.R. gasHigh
Above 60 (140)
LoadMiddle load
Control solenoid valve - E.G.R. valveON (Open)
Control solenoid valve - Throttle valveOFF (Closed)
E.G.R. control valveOpen
Throttle chamber control valveOpen
Amount of E.G.R. gasLow
Above 60 (140)
LoadHigh load
Control solenoid valve - E.G.R. valveOFF (Closed)
Control solenoid valve - Throttle valveOFF (Closed)
E.G.R. control valveClosed
Throttle chamber control valveOpen
Amount of E.G.R. gas