Nissan 100NX N14 silhouetteN14

Electrical Components Inspection (Cont'd)

EF & EC-637prose procedure

Wastegate valve control solenoid, wastegate valve actuator, and recirculation valve are turbo (SR20DET) components.

TROUBLE DIAGNOSES

Electrical Components Inspection (Cont'd)

WASTEGATE VALVE CONTROL SOLENOID VALVE

Check air passage continuity.

Wastegate valve control solenoid valve air passage continuity

12V direct current supply between terminals ⓐ and ⓑ
Air passage continuity between ⓐ and ⓑYes
No supply
Air passage continuity between ⓐ and ⓑNo
If N.G., replace solenoid valve.

WASTEGATE VALVE ACTUATOR

Apply compressed air to wastegate valve actuator and check it for smooth movement.
The air pressure should be in the range of 59 to 69 kPa (0.59 to 0.69 bar, 0.6 to 0.7 kg/cm², 9 to 10 psi).

RECIRCULATION VALVE

Check air passage continuity.

Recirculation valve air passage continuity

A vacuum of above −17.3 kPa (−173 mbar, −130 mmHg, −5.12 inHg) is applied to vacuum port
Air passage continuity between ⓐ and ⓑYes
No vacuum applied
Air passage continuity between ⓐ and ⓑNo
If N.G., replace recirculation valve.